Quality Control Technician
Advanced Industrial Devices
Invite-only right now: save jobs, track applications, build tailored resumesAlready have an account? Log in
- Location
- Fort Mill, SC
- Work style
- On-site
- Job type
- Full time
- Posted
- Oct 1
- 19 days ago
Career path
See where this role leads
Jigup maps the next three moves from a job like this one, with the titles and the skills each step asks for.
About the company
Advanced Industrial Devices
Mechanical or industrial engineering · 51 to 200 employees
AID builds UL508A industrial control panels.
What you'll do
- Perform quality control inspection and factory acceptance testing on UL 508A control panels prior to shipment, including function testing of relay logic and PLC input/output against motor starters, drives, and other field devices
- Accurately complete test reports, inspection checklists, and other QC documentation
- Maintain working technical fluency with UL 508A panel builds (able to read prints, understand wiring/BOM discrepancies, and speak credibly with builders about a technical issue)
- Identify and document quality issues prior to shipment and coordinate corrective action with Production and Engineering
What you need
- Represent AID as a professional in both shop and customer-facing field environment
- Self-motivated and team oriented, with the composure to manage a customer relationship on-site under pressure
- Working knowledge of pumps, pump stations, or similar mechanical/motor-driven equipment
- Minimum two years of automation experience preferred, including various types of sensors, analog and digital inputs/outputs, and testing/calibration of valves and transmitters
- Competent in reading and understanding electronic/electrical schematic diagrams
- Able to diagnose system failures using methodical, logical troubleshooting practices; proficient in technical writing
- Willingness and ability to travel (approximately 20% of the role) for field startupsand modifications
- Prior field service, commissioning, or customer-facing technical support experience preferred
- Excellent written and verbal communication skills are required
- Effective planning, problem solving, and decision-making skills are essential
Key skills
UL 508ATroubleshootingTechnical writingPLC operationVariable frequency drive programmingPLC flashing/setupTesting/calibrationElectrical/electronic test equipmentPump systemsRelay logicSerial communicationPlanningProblem solving
Keywords for your resumePro
The words this employer's screening is likely to look for.
This job lists resume keywords
The terms this posting uses, pulled out so you can mirror them in your resume. Jigup Pro members see the list on the job board.
See full description on company page, apply now
Read the full posting here
Job Title: QC Technician Location: Fort Mill, SC Department: Quality Reports To : Quality Manager Job Type: Full-Time Summary: AID builds UL508A industrial control panels. In this role, you will be working closely with the operations team to ensure every panel that leaves Fort Mill is of the highest quality and meets all customer expectations. Approximately 80% of your time will be spent in-house performing quality control and testing on panels prior to shipment; the remaining 20% will involve travel to end-user job sites for pump start-ups, control panel commissioning, and field modifications. This is a hands-on role. You are the last eyes on a panel before it ships to a customer, and the face of AID in the field during commissioning and troubleshooting. AID is in an active growth phase, transitioning to enterprise systems and building scalable production infrastructure. The right candidate thrives in a dynamic, fast-paced environment, and is ready to help shape the future of AID. Responsibilities: QC & In-House Testing Perform quality control inspection and factory acceptance testing on UL 508A control panels prior to shipment, including function testing of relay logic and PLC input/output against motor starters, drives, and other field devices Accurately complete test reports, inspection checklists, and other QC documentation Maintain working technical fluency with UL 508A panel builds (able to read prints, understand wiring/BOM discrepancies, and speak credibly with builders about a technical issue) Identify and document quality issues prior to shipment and coordinate corrective action with Production and Engineering Field Startup & Commissioning (~20% of time) Lead and support on-site pump control panel commissioning, startup, troubleshooting, and end-user training Perform field modifications, upgrades, or recommended design changes to control panels, field devices, and associated components Provide technical leadership during field activities and coordinate with internal and external stakeholders Serve as the primary point of contact on-site, communicating clearly and calmly with customers on system status, issues, and resolutions. This includes situations where something isn't working as expected Provide diagnostic guidance and technical assistance to internal and external customers General Knowledgeable of pump systems and pump station operation (centrifugal pumps, motor starters, VFDs, soft starts) as well as three-phase/single-phase power, transformers, relay logic, serial communication, PLC operation, PC-based data-loading programs, and electrical/electronic test equipment and hand tools Variable frequency drive programming and PLC flashing/setup Promote a safe working environment adhering to all safety processes and procedures Promote a culture of teamwork, accountability, and customer focus Reports to the QC Lead Requirements: Represent AID as a professional in both shop and customer-facing field environment Self-motivated and team oriented, with the composure to manage a customer relationship on-site under pressure Working knowledge of pumps, pump stations, or similar mechanical/motor-driven equipment Minimum two years of automation experience preferred, including various types of sensors, analog and digital inputs/outputs, and testing/calibration of valves and transmitters Competent in reading and understanding electronic/electrical schematic diagrams Able to diagnose system failures using methodical, logical troubleshooting practices; proficient in technical writing Willingness and ability to travel (approximately 20% of the role) for field startups and modifications Prior field service, commissioning, or customer-facing technical support experience preferred Excellent written and verbal communication skills are required Effective planning, problem solving, and decision-making skills are essential Must submit to pre-employment background, drug, and alcohol screening.