Field Engineer

Hunt Refining

Mcallen, TXFull time
With an account: save jobs, track applications, build tailored resumesAlready have an account? Log in
Location
Mcallen, TX
Job type
Full time
Posted
Nov 2
3 days ago
Career path

See where this role leads

Jigup maps the next three moves from a job like this one, with the titles and the skills each step asks for.

Create an account

About the company

Hunt Refining

Oil & energy · 201 to 500 employees

Hunt Refining on LinkedIn

What you'll do

  • Execute the protection-system maintenance, testing, and compliance data collection required by NERC PRC, CIP, and IRO standards.
  • Execute testing, calibration, and commissioning for SEL and GE protection platforms, SEL RTAC SCADA devices, and DFR equipment; analyze relay event reports and coordinate protection schemes with transmission operations.
  • Maintain the District relay lab and use it to validate firmware, relay settings, and Doble RTS test routines before changes are applied to in-service equipment.
  • Commission new and modified substation equipment, including relay panels, control buildings, and protection and communications infrastructure.
  • Diagnose complex protection-system faults, determine root cause, and direct corrective actions.
  • Coordinate maintenance scheduling under ERCOT seasonal restriction windows; plan and execute outage work within approved windows.
  • Provide protection, control, and automation support for the Sharyland HVDC converter station (Hitachi MACH 2/3 platform), including participation in planned maintenance, thyristor valve inspection, protection-system testing, and control-system verification.
  • Support scope oversight and documentation of Hitachi maintenance activities during OEM field-service windows.
  • Build proficiency on the HVDC platform and document OEM procedures to support HUS’s evaluation of insourcing HVDC maintenance.
  • Other duties as assigned.
  • Reporting to the District Manager, the Field Engineer performs and coordinates protection, control, commissioning, and diagnostic work for the assigned district, with primary responsibility for maintaining substation protection and control (P&C).
  • Working with general supervision, the Field Engineer independently plans and executes relay testing, equipment commissioning, fault diagnosis, and the data collection that supports NERC compliance.
  • HVDC maintenance and reliability at the Sharyland converter station are a district responsibility; within that scope, this role is responsible for HVDC protection, control, and automation.
  • Field-based position assigned to transmission districts; not eligible for remote or hybrid work arrangements. Works in outdoor substation and HVDC station environments, in proximity to high-voltage energized equipment. Participates in the district on-call rotation, with maintenance occasionally scheduled on nights and weekends. Travel between district facilities required; valid Texas driver’s license required.
  • Committed to safe work practices and to compliance with all applicable NERC, ERCOT, and PUCT reliability standards, operating rules, and regulations. Conduct must reflect Hunt and Sharyland core values: Respect for the Individual, Humility, Excellence, Innovation, Teamwork, and Integrity, and comply with the Sharyland Utilities Code of Business Conduct. Must pass a Personnel Risk Assessment before hire and every seven years thereafter.
  • Proficiency with protective relay test equipment (OMICRON, Doble F6150, or equivalent).
  • Ability to read and interpret engineering drawings, protection one-lines, and relay settings files.
  • Relay configuration and event-analysis software experience (SEL AcSELerator, SEL-5030, or equivalent).
  • Excellent field documentation, organizational, and communication skills.
  • Self-directed, professionally mature, and capable of working independently in field environments.
  • Valid Texas driver’s license and clean driving record.
  • Bachelor’s degree in electrical engineering from an ABET-accredited program or a program with recognized equivalency.
  • 7+ years of progressive field experience in protection, control, and relay-systems commissioning, testing, and maintenance.
  • Demonstrated proficiency with protective relay platforms.
  • FE/EIT registration.
  • HVDC system experience (Hitachi, ABB, Siemens, or equivalent converter-station platform).
  • FACTS equipment (SVC, STATCOM) commissioning or maintenance experience (strong differentiator).
  • Familiarity with Doble PowerBase (protection asset and testing database).
  • Familiarity with HVDC converter-station protection and control platforms (Hitachi MACH 2/3) and FACTS devices (SVC, STATCOM).
  • Doble RTS test-system programming proficiency.
  • Proficiency with Microsoft 365 applications.
  • For 90 years, we have nurtured creative ideas and turned them into successful realities using three core strategic pillars – creativity, excellence, and people.
  • 401K – 12% employer contribution with no vesting period (6% Match and 6% non-matching contribution)
  • Highly competitive compensation
  • Hybrid work options available for most roles
  • Five to eight weeks of PTO annually based on years of experience; eleven additional holidays per calendar year
  • All Medical/Dental/Vision benefits start day one with the company; low employee premiums
  • Education Assistance Program
  • Free covered employee parking for Dallas HQ based employees
  • Free specialty coffee bar in the Dallas HQ
  • Onsite breakfast and lunch area in the Dallas HQ
  • Commitment to the following ideals: Work/Life Balance
  • Ongoing professional development opportunities
  • An exceptional employee experience

Key skills

relay testingequipment commissioningfault diagnosisNERC compliancesubstation protection and control

Keywords for your resumePro

The words this employer's screening is likely to look for.

This job lists resume keywords

The terms this posting uses, pulled out so you can mirror them in your resume. Jigup Pro members see the list on the job board.

Create an account

See full description on company page, apply now

Read the full posting here
Reporting to the District Manager, the Field Engineer performs and coordinates protection, control, commissioning, and diagnostic work for the assigned district, with primary responsibility for maintaining substation protection and control (P&C). Working with general supervision, the Field Engineer independently plans and executes relay testing, equipment commissioning, fault diagnosis, and the data collection that supports NERC compliance.

More entry level jobs in Mcallen, TX

All jobs in Mcallen, TX

More jobs at Hunt Refining

Ready to apply?

Create an account to save jobs, track applications, and build tailored resumes.

Create an account